P0141 – O2 Sensor Heater Circuit (Bank 1 Sensor 2)

Description

The ECM detects a malfunction in the heater circuit of the downstream O2 sensor on Bank 1.

Need More Than Just the Fault Code?

A diagnostic scanner with live data, freeze-frame information and the right system access can help you investigate the actual cause before replacing parts.

Compare Diagnostic Scanners

Symptoms

  • Poor fuel economy
  • Delayed catalyst monitoring
  • Check engine light

Causes

  • Failed heater element in O2 sensor
  • Blown fuse
  • Open or shorted wiring
  • Corroded connector

Diagnosis

  • Check heater fuse and power supply
  • Measure heater resistance
  • Verify power and ground at sensor connector
  • Inspect wiring routing and damage

Repair

  • Replace downstream O2 sensor if heater is faulty
  • Repair wiring or connector
  • Replace fuse after correcting cause